B2B

Our services for the company in the field of e-mobility

Our main customers are companies that produce charging stations or charging cables to which we supply control electronics.

EVSE for installation in the charging station

  • TECHNICAL PARAMETERS
  • INSTALLATION REQUIREMENTS
  • FEATURES
TECHNICAL PARAMETERS

Rated charging current:

Own offtake:

Permissible ambient temperature:

Degree of protection:

Aluminum body dimensions:

Power supply connector:

Car side connector:

Uses phase conductors:

Designed in accordance with:

Cable design:

max 3x32A

less than 0,5W

-30°C to +50°C

IP54

5 x 8 x 19 cm (W x H x L), length including bushings 26cm

None – Requires to be built-into charging station

None – Requires to be built-into charging station

1, 2 or 3 depending on the type of connected vehicle

IEC 61851-1, CE, EMC, RoHS

according to customer’s request

INSTALLATION REQUIREMENTS
  • Requires upstream fuse or breaker with maximum value of 3x32A
  • Requires output to Type 2 socket or charging cable ended by Type 1 or Type 2 connector (IEC 62196)
  • Requires wiring of LED outputs to RGB signaling LED – recommended type
  • If the output is connected to a Type 2 socket, it is also recommended to use an electronic lock (solenoid / motor – to be specified when ordering)
FEATURES
  • Continuous monitoring of the protective conductor connection between the supply and EVSE
  • Continuous monitoring of the protective conductor connection between EVSE and vehicle
  • Permanent leakage current monitoring – type A-EV (30mA AC, 6mA DC)
  • Permanent voltage monitoring at the mains input
  • Functional check of switching elements
  • Integrated overheating protection
  • It can be easily integrated into the EVmapa.cz system
  • Charging current can also be controlled via a 0/1 (0V / 3.3V) logic signal, an 0-10V analog signal, or data communication via RS485, RS232 or TTL USART (5V tolerance).
  • Easy billing meter integration
  • Switching elements rated for more than 150% of rated charging current
  • Noiseless operation
  • For extra charge consumption measurement (A, kWh, Hz, power factor…)
  • For extra charge current monitoring at the base of the building or elsewhere in the network – automatic EVSE charging power control
  • OCPP module for extra charge

Customized development

Our development focuses on enhancing and adding new functions to our EVSE according to the wishes of our customers. This is the way we added RS232 / RS485 support in the past and we are going to support RFID cards over the Wiegand protocol, for example.